Sensing head size
14 mm x 30 mm x 60 mm
Type
Amplifier Unit
Power source
DC Three-wires models
Differential distance
10% max. of sensing distance
Power supply voltage
12 to 24 VDC ripple (p-p) 10% max.
Operating voltage range
10 to 30 VDC
Current consumption
45 mA max.
Control output (Output type)
NPN open collector
Control output (Switching capacity)
100 mA max. (30 VDC max.)
Control output (Residual voltage)
0.7 V max.
Indicator
Detection indicator (red), Stability indicator (green)
Operation mode
NO/NC selectable
Ambient temperature (Operating)
-10 to 55 ℃
Ambient temperature (Storage)
-10 to 55 ℃
Ambient humidity (Operating)
35 to 85% RH
Ambient humidity (Storage)
35 to 85% RH
Temperature influence
±10% max. of sensing distance at 23 ℃ in the temperature range of −10 to 55 ℃
Voltage influence
±1% max. of sensing distance at rated voltage in the rated voltage ±20% range
Insulation resistance
Between charged parts and the case: 5 MΩ min. at 500 VDC
Dielectric strength
Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min
Vibration resistance
Destruction: 10 to 55 Hz, 1.5 mm double amplitude each in X, Y, and Z directions for 2 h
Shock resistance
Destruction: 100 m/s2 3 times each in X, Y, and Z directions
Connection method
Pre-wired models (2 m)
Weight
Package: Approx. 50 g
Accessories
Caution labe, Mounting Bracket, Phillips mounting screw, Instruction manual
Amplifier unit/sensor head of combination
E2C-AM4A, E2C-AK4A