100 to 240 V AC (wide-range), 50/60 Hz | ||
85 to 264 V AC, 47 to 63 Hz | ||
100 VA max. | 50 VA max. | |
At 100 to 120 V AC: 15 A/8 ms max. for cold start at roomtemperatureAt 200 to 240 V AC: 30 A/8 ms max. for cold start at roomtemperature | At 100 to 120 V AC:20 A/8 ms max. for cold startat room temperatureAt 200 to 240 V AC:40 A/8 ms max. for cold startat room temperature | |
5.0 A, 5 V DC (including supply to CPU Unit) | 2.8 A, 5 V DC(including supply to CPU Unit) | |
0.8 A, 24 V DC | 0.4 A, 24 V DC | |
Total: 25 W max. | Total: 14 W max. | |
Not provided. | ||
Contact configuration:SPST-NOSwitch capacity:250 V AC, 2 A (resistive load)120 V AC, 0.5 A (inductiveload),24 V DC, 2A (resistive load)24 V DC, 2 A (inductive load) | Not provided. | |
Not provided. | With Alarm output (open-collector output)30 V DC max., 50 mA max. | Not provided. |
20 MΩ min. (at 500 V DC)between AC external andGR terminals *3 | 20 MΩ min. (at 500 V DC)between all externalterminals and GR terminal *3,and between all alarm outputterminals.20 MΩ 1 min. (at 250 V DC)between all alarm outputterminals and GR terminal *3. | 20 MΩ min. (at 500 V DC)between AC external andGR terminals *3 |
2,300 V AC 50/60 Hz for 1 minbetween AC external and GRterminals *3Leakage current: 10 mA max. | 2,300 VAC, 50/60 Hz for 1 minbetween all external terminalsand GR terminal *3 andbetween all alarm outputterminals with a leakagecurrent of 10 mA max.1,000 V AC, 50/60 Hz for 1 minbetween all alarm outputterminals and GR terminal *3with a leakage current of 10mA max. | 2,300 V AC 50/60 Hz for 1 minbetween AC external and GRterminals *3Leakage current: 10 mA max. |
1,000 V AC, 50/60 Hz for 1 minute between DC external and GR terminals *3Leakage current: 10 mA max. | ||
2 kV on power supply line (conforming to IEC61000-4-4) | ||
Conforms to IEC60068-2-65 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 HzAcceleration of 9.8 m/s2for 100 min in X, Y, and Z directions (10 sweeps of 10 min each =100 min) | ||
Conforms to IEC60068-2-27147 m/s2, 3 times in X, Y, and Z directions (100 m/s2for Relay Output Units) | ||
0 to 55 °C | ||
10% to 90% (with nocondensation) | 10% to 90% (with nocondensation) *5 | 10% to 90% (with nocondensation) |
Must be free from corrosive gases. | ||
- 20 to 70 °C (excludingbattery) | - 20 to 75 °C *5 | - 20 to 75 °C (excludingbattery) |
Less than 100 Ω | ||
Mounted in a panel. | ||
350 g max. | 400 g max. | 200 g max. |
90.7 to 466.7 × 90 × 65 mm (W × H × D) (not including cables)Note:W = a + b + 20 × n + 31 × m + 14.7a: Power Supply Unit: PA205R and PA205C = 80; PA202 = 45; PD025 = 60; PD022=27b: CPU Unit: CJ1-H or CJ1 = 62; CJ1M-CPU1[] = 31 *8; CJ1M-CPU2[] = 49 *8The total width is given by the following: W = 156.7 + n × 20 + m × 31,where n is the number of 32-point I/O Units or I/O Control Units and m is the number of otherUnits. | ||
Conforms to cULus and EC Directives. |